Chapter 10: Results
A micro-perforation occurred in seven of the 68 (10%) eyes in which manual dissection with a spatula was performed, and in 4 (50%) eyes in which visco-dissection was performed. In these cases the procedure was converted into a penetrating keratoplasty. In one eye, the interface was later irrigated to remove residual visco elastic.
|